Description:
A Carbon Fiber Head come standard with the system and allows for ease of use and high through-put of samples. Carbon fiber coating involves much more of a "flash evaporation" of the carbon fiber, in a matter of a second or so, the fiber heats up, flashes off carbon and breaks. Carbon gets deposited before the head actually gets a chance to heat up, reducing the time samples are exposed.
A Carbon Rod Head is offered as an option
We suggest a small two stage mechanical pump for use with this system such as the Pfieffer DUO 3
RoHS Compliance
Carbon Coating the SPI-Module Way!
• Small footprint provides significant savings in usable bench space.
• Easily upgraded for extra capabilities. Add a sputter module without having to buy another complete system.
• Specimen chamber: 5" (12.7 cm) High x 4" (10.2 cm) Outside Diameter
• Uniform coating - all shapes, sizes.
• Safety interlocks - ensures that high voltage is not applied until vacuum is achieved.
• Continuously movable sample stage - to easily adjust cathode to sample distance.
• Mobility - compact design allows easy transport from lab to lab.
• Finger bleed vacuum control - with the highest quality needle valve.
• Inert gas entry - inlet in rear.
• Water cooling to sample stage - standard.
• One year warranty.
• CE Certified
• RoHS Compliant
A Carbon Fiber Head come standard with the system and allows for ease of use and high through-put of samples. Carbon fiber coating involves much more of a "flash evaporation" of the carbon fiber, in a matter of a second or so, the fiber heats up, flashes off carbon and breaks. Carbon gets deposited before the head actually gets a chance to heat up, reducing the time samples are exposed.
A Carbon Rod Head is offered as an option
We suggest a small two stage mechanical pump for use with this system such as the Pfieffer DUO 3
RoHS Compliance
Carbon Coating the SPI-Module Way!
• Small footprint provides significant savings in usable bench space.
• Easily upgraded for extra capabilities. Add a sputter module without having to buy another complete system.
• Specimen chamber: 5" (12.7 cm) High x 4" (10.2 cm) Outside Diameter
• Uniform coating - all shapes, sizes.
• Safety interlocks - ensures that high voltage is not applied until vacuum is achieved.
• Continuously movable sample stage - to easily adjust cathode to sample distance.
• Mobility - compact design allows easy transport from lab to lab.
• Finger bleed vacuum control - with the highest quality needle valve.
• Inert gas entry - inlet in rear.
• Water cooling to sample stage - standard.
• One year warranty.
• CE Certified
• RoHS Compliant